Rack PDU 2G, Metered-by-Outlet, ZeroU, 32A, 230V, (21) C13 & (3) C19

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Overview
    Description
    APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection. Current metering provides real-time remote monitoring of connected loads. Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
    Model Name
    Rack PDU 2G, Metered-by-Outlet, ZeroU, 32A, 230V, (21) C13 & (3) C19
    Includes
    CAN Port Terminator , Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable
    Standard Lead Time
    Usually in Stock
    Product Distribution
    Afghanistan , Albania , Algeria , Andorra , Angola , Armenia , Australia , Austria , Azerbaijan , Bahrain , Bangladesh , Belarus , Belgium , Benin , Bhutan , Bosnia And Herzegovina , Botswana , Brazil , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Central African Republic , Chad , China , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Cote D'Ivoire , Croatia , Cyprus , Czech Republic , Denmark , Djibouti , East Timor , Egypt , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Guadeloupe , Guinea , French Guiana , Hong Kong , Hungary , Iceland , India , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jordan , Kazakhstan , Kenya , KOREA, REPUBLIC OF , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Malaysia , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , New Zealand , Niger , Nigeria , Norway , Oman , Pakistan , Papua New Guinea , Philippines , Poland , Portugal , Qatar , Reunion , Romania , Russian Federation , Rwanda , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sri Lanka , Sudan , Suriname , Sweden , Switzerland , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , Uzbekistan , Viet Nam , Western Sahara , Yemen , Zambia , Zimbabwe
    Output
    Nominal Output Voltage
    230V
    Maximum Total Current Draw per Phase
    32 A
    Output Connections
    (21) IEC 320 C13 (Battery Backup) , (3) IEC 320 C19 (Battery Backup)
    Overload Protection
    Yes
    Input
    Nominal Input Voltage
    200V , 208V , 230V
    Input Frequency
    50/60 Hz
    Input Connections
    IEC 309 32A 2P+E
    Cord Length
    3 meters
    Number of Power Cords
    1
    Acceptable Input Voltage
    220-240 VAC
    Maximum Line Current per phase
    32 A
    Maximum Input Current per phase
    32 A
    Load Capacity
    7400 VA
    Physical
    Net Weight
    8.22 kg
    Maximum Height
    1829.0 mm
    Maximum Width
    56.0 mm
    Maximum Depth
    51.0 mm
    Shipping Weight
    10.48 kg
    Shipping Height
    2037.0 mm
    Shipping Width
    163.0 mm
    Shipping Depth
    117.0 mm
    Color
    Black
    Environmental
    Operating Environment
    -5 - 45 °C
    Operating Relative Humidity
    5 - 95 %
    Operating Elevation
    0-3000 meters
    Storage Temperature
    -25 - 65 °C
    Storage Relative Humidity
    5 - 95 %
    Storage Elevation
    0-15000 meters
    Conformance
    Approvals
    EN 55022 Class A , EN 55024 , EN 61000-3-2 , EN 61000-3-3 , VDE
    Standard warranty
    2 years repair or replace
    Sustainable Offer Status
    RoHS
    Compliant
    REACH
    REACH: Contains No SVHCs
    Battery Directive
    Compliant
  • Documents & Downloads

    Language
    • English
    • Latvian
    • Slovenian
    • Danish
    • Lithuanian
    • Greek
    • Croatian
    • Serbian
    • Finnish
    • Norwegian
    • Dutch
    • Estonian
    Catalogue
    Date
    Size
    Add to My Documents
    Rack Power Distribution Unit (PDU) Pocket Guide (Version 2)
    User guide
    Date
    Size
    Add to My Documents
    Release Notes AP7XXXB, AP8XXX Rack PDUs AOS/APP V 6.7.2 (Version 5)
    Release Notes Metered and Switched (AP8xxx) Rack Power Distribution Unit (PDU) v6.4.0 (Version 8)
    CAD
    Date
    Size
    Add to My Documents
    AP8453 - Rack PDU 2G, Metered-by-Outlet, ZeroU, 32A, 230V, (21) C13 & (3) C19 (Version 0)
    Specification guide
    Date
    Size
    Add to My Documents
    Rack Power Distribution Unit (AP8453) Overview and Specifications (Version 0)
    Certificate
    Date
    Size
    Add to My Documents
    CCC Exemption Letter (Version 2)
    Date 4/5/19
    Size 4.4 MB
    EU Declaration of Conformity - Rack Power Distribution Unit (PDU) (AP84XX) (Version 0)
    EAC for Russian Customs Union - Rack PDUs and In Line Current Meters (Version 2)
    ACMA Supplier's DoC - Rack Power Distribution Units (Version 0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.