Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

    ATV310HU75N4E Product picture Schneider Electric

    Range: Altivar Easy 310

    variable speed drives

    ATV310HU75N4E

    ATV310HU75N4E Product picture Schneider Electric
    Range: Altivar Easy 310

    variable speed drives

    ATV310HU75N4E

    variable speed drive ATV310 - 7.5 kW - 10 hp - 380...460 V - 3 phase

    Show more characteristics >
    Add to My Favourites Remove from My Favourites

    • Main
      range of product
      Altivar Easy 310
      product or component type
      Variable speed drive
      product specific application
      Simple machine
      assembly style
      With heat sink
      device short name
      ATV310
      network number of phases
      Three phase
      [Us] rated supply voltage
      380...460 V (- 15...10 %)
      motor power kW
      7.5 kW
      motor power hp
      10 hp
      noise level
      50 dB
      Complementary
      product destination
      Asynchronous motors
      quantity per set
      Set of 1
      EMC filter
      Without EMC filter
      type of cooling
      Integrated fan
      supply frequency
      50/60 Hz +/- 5 %
      communication port protocol
      Modbus
      connector type
      RJ45 for Modbus on front face
      physical interface
      2-wire RS 485 for Modbus
      transmission frame
      RTU for Modbus
      transmission rate
      4800 bit/s
      9600 bit/s
      19200 bit/s
      38400 bit/s
      number of addresses
      1...247 addresses for Modbus
      communication service
      Read holding registers (03), messaging: 29 words
      Write single register (06), messaging: 29 words
      Write multiple registers (16), messaging: 27 words
      Read/write multiple registers (23), messaging: 4/4 words
      Read device identification (43)
      line current
      22.4 A
      apparent power
      17.8 kVA
      prospective line Isc
      <= 5 kA
      continuous output current
      17 A at 4 kHz
      maximum transient current
      25.5 A for 60 s
      power dissipation in W
      203.87 W at In
      speed drive output frequency
      0.5...400 Hz
      nominal switching frequency
      4 kHz
      switching frequency
      2...12 kHz (adjustable)
      speed range
      1...20
      transient overtorque
      170...200 % of nominal motor torque depending on drive rating and type of motor
      braking torque
      Up to 150 % of nominal motor torque with braking resistor at high inertia
      Up to 70 % of nominal motor torque without braking resistor
      asynchronous motor control profile
      Energy saving ratio
      Quadratic voltage/frequency ratio
      Sensorless flux vector control
      motor slip compensation
      Adjustable
      Preset in factory
      output voltage
      380...460 V three phase
      electrical connection
      6...10 mm² at terminal L1, L2, L3, PA/+, PB, U, V, W
      tightening torque
      2.2...2.4 N.m
      insulation
      Electrical between power and control
      supply
      Internal supply for reference potentiometer : 5 V (4.75...5.25 V) DC 10 mA with overload and short-circuit protection
      Internal supply for logic inputs : 24 V (20.4...28.8 V) DC 100 mA with overload and short-circuit protection
      analogue input number
      1
      analogue input type
      Configurable current (AI1) 0...20 mA, impedance 250 Ohm
      Configurable voltage (AI1) 0...10 V, impedance 30 kOhm
      Configurable voltage (AI1) 0...5 V, impedance 30 kOhm
      discrete input number
      4
      discrete input type
      24 V (18...30 V) programmable, at LI1...LI4 terminal(s)
      discrete input logic
      Positive logic (source), 0...< 5 V (state 0), > 11 V (state 1)
      Negative logic (sink), > 16 V (state 0), < 10 V (state 1), input impedance 3.5 kOhm
      sampling duration
      10 ms for analogue input
      20 ms, tolerance +/- 1 ms for logic input
      linearity error
      +/- 0.3 % of maximum value for analogue input
      analogue output number
      1
      analogue output type
      AO1 software-configurable voltage : 0...10 V, impedance: 470 Ohm, resolution 8 bits
      AO1 software-configurable current : 0...20 mA, impedance: 800 Ohm, resolution 8 bits
      discrete output number
      2
      discrete output type
      (LO+, LO-) logic output
      (R1A, R1B, R1C) protected relay output 1 C/O
      minimum switching current
      5 mA at 24 V DC for logic relay
      maximum switching current
      2 A at 250 V AC on inductive load (cos phi = 0.4 L/R = 7 ms) for logic relay
      2 A at 30 V DC on inductive load (cos phi = 0.4 L/R = 7 ms) for logic relay
      3 A at 250 V AC on resistive load (cos phi = 1 L/R = 0 ms) for logic relay
      4 A at 30 V DC on resistive load (cos phi = 1 L/R = 0 ms) for logic relay
      acceleration and deceleration ramps
      S
      U
      Linear from 0...999.9 s
      braking to standstill
      By DC injection, <= 30 s
      protection type
      Against input phase loss in three-phase
      Thermal motor protection via the drive by continuous calculation of I²t
      Line supply overvoltage
      Line supply undervoltage
      Overcurrent between output phases and earth
      Overheating protection
      Short-circuit between motor phases
      frequency resolution
      Converter A/D, 10 bits for analog input
      0.1 Hz for display unit
      time constant
      20 ms, tolerance +/- 1 ms for reference change
      operating position
      Vertical +/- 10 degree
      height
      171 mm
      width
      150 mm
      depth
      232 mm
      product weight
      3.7 kg
      Environment
      electromagnetic compatibility
      Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11
      Electrical fast transient/burst immunity test (test level: level 4) conforming to EN/IEC 61000-4-4
      Electrostatic discharge immunity test (test level: level 3) conforming to EN/IEC 61000-4-2
      Immunity to conducted disturbances (test level: level 3) conforming to EN/IEC 61000-4-6
      Radiated radio-frequency electromagnetic field immunity test (test level: level 3) conforming to EN/IEC 61000-4-3
      Surge immunity test (test level: level 3) conforming to EN/IEC 61000-4-5
      standards
      EN/IEC 61800-3
      EN/IEC 61800-5-1
      IP degree of protection
      IP41 on top
      IP20 without blanking plate on upper part
      pollution degree
      2 conforming to EN/IEC 61800-5-1
      environmental characteristic
      Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
      Dust pollution resistance class 3S2 conforming to EN/IEC 60721-3-3
      shock resistance
      15 gn (duration = 11 ms) conforming to EN/IEC 60068-2-27
      relative humidity
      5...95 % (without condensation) conforming to IEC 60068-2-3
      5...95 % (without dripping water) conforming to IEC 60068-2-3
      ambient air temperature for storage
      -25...70 °C
      ambient air temperature for operation
      -10...55 °C without derating
      55...60 °C protective cover from the top of the drive removed with current derating 2.2 % per °C
      operating altitude
      <= 1000 m without derating
    • Documents & Downloads

      Language
      • English
      Catalogue
      Date
      Size
      Add to My Documents
      Date 12/9/17
      Size 1.7 MB
      User guide
      Date
      Size
      Add to My Documents
      Date 17/3/16
      Size 1.1 MB
      Date 14/1/15
      Size 638.1 KB
      Date 14/3/17
      Size 469.1 KB
      Date 23/5/18
      Size 7.8 MB
      Certificate
      Date
      Size
      Add to My Documents
      Date 22/6/18
      Size 690.6 KB
      Instruction sheet
      Date
      Size
      Add to My Documents
      Date 25/7/18
      Size 5.4 MB
      Product environmental
      Date
      Size
      Add to My Documents
      Date 27/3/18
      Size 1.1 MB
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
    • Dimensions Drawings

      Dimensions


      Dimensions in mm

      a

      b

      c

      G

      H

      H1

      Ø

      For screws

      150

      220

      171

      130

      210

      232

      5

      M4

      Dimensions in in.

      a

      b

      c

      G

      H

      H1

      Ø

      For screws

      5.91

      8.66

      6.73

      5.12

      8.27

      9.13

      0.20

      M4


    • Mounting and Clearance

      Mounting Recommendations
      Clearance


      Mounting Types

      Mounting Type A


      Mounting Type B


      Remove the protective cover from the top of the drive.


    • Connections and Schema

      Three-Phase Power Supply Wiring Diagram


      A1 :
      Drive
      KM1 :
      Contactor (only if a control circuit is needed)
      P1 :
      2.2 kΩ reference potentiometer. This can be replaced by a 10 kΩ potentiometer (maximum).
      Q1 :
      Circuit breaker
      R :
      Braking resistor (optional)
      (1)
      Negative logic (Sink)
      (2)
      Positive logic (Source) (factory set configuration)
      (3)
      0...10 V or 0...20 mA
      (4)
      Line choke three-phase (optional)