Rear Module Controller panel - Dig 16 inputs/10 outputs

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Magelis SCU
    product or component type
    Controller
    device presentation
    Basic element
    Complementary
    supply
    External source
    [Us] rated supply voltage
    24 V at 20.4...28.8 V DC
    immunity to microbreaks
    <= 10 ms
    inrush current
    <= 30 A
    power consumption in W
    15 W
    local signalling
    No indicator
    number of pages
    Limited by internal memory capacity
    software designation
    SoMachine
    operating system
    Magelis
    processor name
    CPU RISC
    processor frequency
    333 MHz
    memory description
    128 MB flash memory, type: NAND
    128 kB internal data storage memory, type: FRAM
    128 MB application run memory, type: DRAM
    integrated connection type
    1 RJ45 connector serial link with RS232/RS485 interface at <= 115.2 kbits/s
    1 RJ45 connector Ethernet TCP/IP
    1 USB 2.0 type mini B
    1 USB 2.0 type A
    SUB-D 9 connector CANopen master bus
    realtime clock
    Built-in
    downloadable protocols
    Modbus
    Modbus TCP/IP
    CANopen
    fixing mode
    By 1 nut - diameter: Ø 22 mm, mounting on: 1...6 mm thick panel
    enclosure material
    PC/PBT
    shock resistance
    147 m/s² (duration=11 ms) conforming to IEC 60068-2-27 on DIN rail
    294 m/s² (duration=6 ms) conforming to IEC 60068-2-27 on panel mounting
    vibration resistance
    +/- 3.5 mm (f=5...9 Hz) conforming to IEC 60068-2-6
    1 gn (f=9...150 Hz) conforming to IEC 60068-2-6
    electromagnetic compatibility
    Electrostatic discharge immunity test - test level: 8 kV, air discharge conforming to IEC 61000-4-2
    Electrostatic discharge immunity test - test level: 6 kV, contact discharge conforming to IEC 61000-4-2
    Susceptibility to electromagnetic fields - test level: 10 V/m, 80 MHz...3 GHz conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test - test level: 2 kV, power lines conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test - test level: 1 kV, between analogue I/O and operating voltage conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test - test level: 2 kV, relay wires conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test - test level: 1 kV, Ethernet line conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test - test level: 1 kV, COM line conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test - test level: 1 kV, CAN line conforming to IEC 61000-4-4
    Surge immunity test - test level: 2 kV, power supply (common mode) conforming to IEC 61000-4-5
    Surge immunity test - test level: 1 kV, power supply (differential mode) conforming to IEC 61000-4-5
    Surge immunity test - test level: 1 kV common mode, digital I/O conforming to IEC 61000-4-5
    Surge immunity test - test level: 0.5 kV differential mode, digital I/O conforming to IEC 61000-4-5
    Conducted RF disturbances - test level: 10 V, 0.15...80 MHz conforming to IEC 61000-4-6
    Conducted emission - test level: 150 kHz...30 MHz conforming to EN 55011
    Radiated emission - test level: 30 MHz...1 GHz conforming to EN 55011
    discrete input number
    2 for fast input (normal mode) conforming to IEC 61131-2 Type 1
    14 for digital input conforming to IEC 61131-2 Type 1
    discrete input voltage
    24 V DC discrete input logic:sink or source (positive/negative)
    number of common point
    1 for fast input (HSC mode)
    2 for digital input
    discrete input current
    7.83 mA for fast input
    5 mA for digital
    input impedance
    4.7 kOhm
    2.81 kOhm
    sensor power supply
    15...28.8 V DC, voltage (state 1): >= 15 V, current (state 1): >= 5 mA, voltage (state 0): <= 5 V, current (state 0): <= 1.5 mA
    15...28.8 V DC, voltage (state 1): >= 15 V, current (state 1): >= 2.5 mA, voltage (state 0): <= 5 V, current (state 0): <= 1 mA
    configurable filtering time
    0 ms no filter (none)
    0.004...0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2))
    3...12 ms integrator (none/run/stop)
    input frequency
    100 kHz for fast input (encoder mode) - control type A/B
    100 kHz for fast input - control type single phase
    100 kHz for fast input - control type pulse/direction
    cable distance between devices
    Shielded cable: 10 m for fast input
    Shielded cable: 100 m for digital input
    Unshielded cable: 50 m for digital input
    connection pitch
    3.5 mm
    overvoltage protection
    With
    isolation between channels and internal logic
    500 V DC
    isolation between channels
    None
    discrete output number
    2 fast output (normal mode), output logic: source
    8 digital output, output logic: source
    discrete output voltage
    24 V DC (voltage limit: 19.2...28.8 V) with transistor discrete output(s)
    24 V DC (voltage limit: 5...30 V) with relay discrete output(s)
    220 V AC (voltage limit: 100...250 V) with relay discrete output(s)
    input/output number
    2 for fast input, terminal(s): FI0...FI1
    14 for digital input, terminal(s): DI0...DI13
    2 for fast output, terminal(s): FQ0...FQ1
    8 for digital output, terminal(s): DQ0...DQ7
    discrete output current
    300 mA, response time 2 ms for fast output (normal mode)
    50 mA, response time 2 ms for fast output (PWM or PTO mode)
    2 A (current per output common:4 A), response time 5 ms with opening contact for digital output
    2 A (current per output common:4 A), response time 2 ms with closing contact for digital output
    insulation resistance
    > 10 MOhm between the I/O and internal logic
    > 10 MOhm between power supply and earth
    output frequency
    <= 100 kHz for fast output (PTO mode)
    <= 1 kHz for fast output (PWM mode)
    absolute accuracy error
    +/- 0.1 % of full scale of cyclic ratio 1...99% for fast output (PWM or PTO mode)
    1 % of full scale of cyclic ratio 1...99% for fast output (PWM or PTO mode)
    +/- 5 % of full scale of cyclic ratio 10...90% for fast output (PWM or PTO mode)
    +/- 10 % of full scale of cyclic ratio 20...80% for fast output (PWM or PTO mode)
    +/- 15 % of full scale of cyclic ratio 30...70% for fast output (PWM or PTO mode)
    height
    50.65 mm
    width
    128 mm
    depth
    102 mm
    product weight
    0.359 kg
    Environment
    standards
    EN 61131-2
    FCC Class A
    IEC 61000-6-2
    RoHS compliant
    UL 508
    ANSI/ISA 12-12-01
    WEEE directive 2002/96/EC
    CSA C22.2 No 213 Class I Division 2
    RoHS China SJ/T 11363-2006
    product certifications
    C-Tick
    CULus 508
    GOST
    CUL 1604 Class 1 Division 2
    KCC
    CULus CSA 22-2 No 142
    marking
    CE
    ambient air temperature for operation
    0...50 °C
    ambient air temperature for storage
    -20...60 °C
    relative humidity
    5...85 % without condensation
    operating altitude
    <= 2000 m
    storage altitude
    0...10000 m
    maximum pressure
    800...1114 hPa
    IP degree of protection
    IP65 for front panel conforming to IEC 60529
    IP20 for rear panel conforming to IEC 60529
    NEMA degree of protection
    NEMA 4X for front panel
    pollution degree
    2 conforming to IEC 60664
    environmental characteristic
    Corrosive gas free
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
  • Documents & Downloads

    Language
    • English
    Catalogue
    Date
    Size
    Add to My Documents
    Magelis™ SCU Small HMI Controllers (Version 4.0)
    User guide
    Date
    Size
    Add to My Documents
    Magelis SCU - HMI Controller, Quick Reference Guide (Version 00)
    Magelis SCU - HMI Controller, PTO/PWM Library Guide (Version 05)
    Magelis SCU - HMI Controller, PLCSystem Library Guide (Version 03)
    Magelis SCU - HMI Controller, HSC Library Guide (Version 04)
    Magelis SCU - HMI Controller, Quick Reference Guide (Version 02)
    Magelis SCU HMI Controller, Hardware Guide (Version 05)
    Magelis SCU - HMI Controller, Programming guide (Version 06)
    CAD
    Date
    Size
    Add to My Documents
    Compact CANopen HMI Controller SCU - - Wiring Diagram (Version 1.0)
    CAD files for HMISAC: Micro HMI controller Magelis SCU A (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    HazLoc_UL_NRAG.E486185 _ALL_JUL2018 (Version 1.0)
    HazLoc_cUL_NRAG7.E486185 _ALL_JUL2018 (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    HMIZSURDP.. Remote Controller Module Connection Cable, Instruction Sheet (Version 01)
    Magelis HMISTU and HMISCU Terminals ATEX/IECEx, Instruction Guide (Version 01)
    End of Life Information
    Date
    Size
    Add to My Documents
    Magelis SCU, Product End-of-Life Instructions (Version 1.0)
    Marine certificate
    Date
    Size
    Add to My Documents
    LR_C1210041E2_GTO_STO_SCU_STU_XBTGT (Version 1.0)
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Magelis SCU, Product Environmental Profile (Version 1.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



  • Mounting and Clearance

    Recommended Mounting position


    (1)
    Horizontal mounting
    (2)
    Vertical mounting


    No Recommended Mounting Position



    Clearance


    Keep adequate spacing for proper ventilation to maintain an ambient temperature between 0...50 °C (32...122 °F) for horizontal installation and 0...40 °C (32...104 °F) for vertical installation.


  • Connections and Schema

    Wiring Diagram


    (1)
    Slow-blow 2A type T fuse


    Wiring Diagram of Digital Inputs


    (1)
    HSC inputs with pin assignment of terminal blocks C,D.
    (2)
    Digital inputs with pin assignment of terminal blocks C,D.


    Wiring Diagram of Digital Outputs


    (1)
    Digital outputs with pin assignment of terminal blocks A,B.
    (2)
    PWM outputs with pin assignment of terminal blocks C,D.
    (L)
    Load