
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 200 A - 250 V DC standard coil
Show more characteristics >-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Resistive loadutilisation category AC-1poles description 4Ppower pole contact composition 4 NO[Ue] rated operational voltage <= 460 V DC for power circuit<= 1000 V AC 25...400 Hz for power circuit[Ie] rated operational current 200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuitcontrol circuit type DC standard[Uc] control circuit voltage 250 V DC[Uimp] rated impulse withstand voltage Conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 200 A at <= 60 °C for power circuitIrms rated making capacity 1260 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 1100 A <= 40 °C 1 s power circuit250 A <= 40 °C 10 min power circuit550 A <= 40 °C 1 min power circuit950 A <= 40 °C 10 s power circuitassociated fuse rating 200 A gG at <= 690 V coordination type 2 for power circuit250 A gG at <= 690 V coordination type 1 for power circuitaverage impedance 0.6 mOhm at 50 Hz - Ith 200 A for power circuit[Ui] rated insulation voltage 1000 V for power circuit conforming to IEC 60947-4-1600 V for power circuit certifications CSA600 V for power circuit certifications ULelectrical durability 0.8 Mcycles 200 A AC-1 at Ue <= 440 Vpower dissipation per pole 24 W AC-1safety cover Withmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications BVCCCCSADNVGLGOSTLROS (Lloyds register of shipping)RINAULconnections - terminals Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable endControl circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable endControl circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable endControl circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable endPower circuit : connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - without cable endPower circuit : connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - without cable endPower circuit : connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - with cable endPower circuit : connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - with cable endPower circuit : connector 1 cable(s) 10...120 mm² - cable stiffness: solid - without cable endPower circuit : connector 2 cable(s) 10...50 mm² - cable stiffness: solid - without cable endtightening torque Control circuit : 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit : 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit : 12 N.m - on connector hexagonal 4 mmoperating time 20...35 ms closing40...75 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 8 Mcyclesoperating rate 1200 cyc/h at <= 60 °CComplementary coil technology With integral suppression devicecontrol circuit voltage limits 0.75...1.2 Uc operational at 55 °C, DC0.15...0.4 Uc drop-out at 55 °C, DCtime constant 25 msinrush power in W 270...365 W at 20 °Chold-in power consumption in W 2.4...5.1 W at 20 °CEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5...60 °Cambient air temperature for storage -60...80 °Cpermissible ambient air temperature around the device -40...70 °C at Ucoperating altitude 3000 m without derating in temperaturefire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor closed 15 Gn for 11 msShocks contactor open 6 Gn for 11 msheight 158 mmwidth 150 mmdepth 132 mmproduct weight 2.86 kgOffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Contractual warranty Warranty period 18 months -
Documents & Downloads
Language- English
End of Life InformationSizeAdd to My DocumentsTeSys D LC1 D115-D150 - EoLi (Version 2.0)Product Environmental ProfileSizeAdd to My DocumentsPEP - TeSys D LC1D115 to D150 contactors (Version 2.0)REACh DeclarationSizeAdd to My DocumentsDate 23/11/18Size 0EU RoHS DeclarationSizeAdd to My DocumentsDate 23/11/18Size 0 -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.