
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 220 V DC standard coil
Show more characteristics >-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Motor controlResistive loadutilisation category AC-1AC-3poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage <= 300 V DC for power circuit<= 1000 V AC 25...400 Hz for power circuit[Ie] rated operational current 200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit115 A (<= 60 °C) at <= 440 V AC AC-3 for power circuitmotor power kW 30 kW at 220...230 V AC 50/60 Hz55 kW at 380...400 V AC 50/60 Hz65 kW at 1000 V AC 50/60 Hz75 kW at 500 V AC 50/60 Hz80 kW at 660...690 V AC 50/60 Hz59 kW at 415...440 V AC 50/60 Hzmotor power HP (UL / CSA) 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors40 hp at 230/240 V AC 50/60 Hz for 3 phases motors75 hp at 460/480 V AC 50/60 Hz for 3 phases motors100 hp at 575/600 V AC 50/60 Hz for 3 phases motorscontrol circuit type DC standard[Uc] control circuit voltage 220 V DCauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage Conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 200 A at <= 60 °C for power circuitIrms rated making capacity 1260 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 1100 A <= 40 °C 1 s power circuit100 A 1 s signalling circuit120 A 500 ms signalling circuit140 A 100 ms signalling circuit250 A <= 40 °C 10 min power circuit550 A <= 40 °C 1 min power circuit950 A <= 40 °C 10 s power circuitassociated fuse rating 200 A gG at <= 690 V coordination type 2 for power circuit250 A gG at <= 690 V coordination type 1 for power circuit10 A gG for signalling circuitaverage impedance 0.6 mOhm at 50 Hz - Ith 200 A for power circuit[Ui] rated insulation voltage 1000 V for power circuit conforming to IEC 60947-4-1600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for signalling circuit conforming to IEC 60947-1600 V for signalling circuit certifications CSA600 V for signalling circuit certifications ULelectrical durability 0.8 Mcycles 200 A AC-1 at Ue <= 440 V0.95 Mcycles 115 A AC-3 at Ue <= 440 Vpower dissipation per pole 24 W AC-17.9 W AC-3safety cover Withoutmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications BVCCCCSADNVGLGOSTLROS (Lloyds register of shipping)RINAULconnections - terminals Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable endControl circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable endControl circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable endControl circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable endPower circuit : connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - without cable endPower circuit : connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - without cable endPower circuit : connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - with cable endPower circuit : connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - with cable endPower circuit : connector 1 cable(s) 10...120 mm² - cable stiffness: solid - without cable endPower circuit : connector 2 cable(s) 10...50 mm² - cable stiffness: solid - without cable endtightening torque Control circuit : 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit : 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit : 12 N.m - on connector hexagonal 4 mmoperating time 20...35 ms closing40...75 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 8 Mcyclesoperating rate 1200 cyc/h at <= 60 °CComplementary coil technology With integral suppression devicecontrol circuit voltage limits 0.75...1.2 Uc operational at 55 °C, DC0.15...0.4 Uc drop-out at 55 °C, DCtime constant 25 msinrush power in W 270...365 W at 20 °Chold-in power consumption in W 2.4...5.1 W at 20 °Cauxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact)insulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5...60 °Cambient air temperature for storage -60...80 °Cpermissible ambient air temperature around the device -40...70 °C at Ucoperating altitude 3000 m without derating in temperaturefire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor closed 15 Gn for 11 msShocks contactor open 6 Gn for 11 msheight 158 mmwidth 120 mmdepth 132 mmproduct weight 2.5 kgOffer Sustainability RoHS (date code: YYWW) Contractual warranty Warranty period 18 months -
Documents & Downloads
Language- English
EU RoHS DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.