India
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all EM6400NG
METSEEM6400NGRSCL2 Product picture Schneider Electric

METSEEM6400NGRSCL2

METSEEM6400NGRSCL2 Product picture Schneider Electric
METSEEM6400NGRSCL2

Conzerv Power and Energy meter - inst., pulse, RS485, THD, 15th Har, Class 0.2

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    Conzerv
    product name
    EM6400NG RS-485
    device short name
    Conzerv EM6400NG
    product or component type
    Energy meter
    Complementary
    power quality analysis
    up to the 15th harmonic
    device application
    Power monitoring
    type of measurement
    Current
    Voltage
    Frequency
    Apparent energy
    Apparent power
    Active and reactive energy
    Active and reactive power
    metering type
    Demand current I1, I2, I3
    Active, reactive, apparent energy (signed, four quadrant)
    Active power P, P1, P2, P3
    Unbalance current
    Average current Iavg
    Peak demand currents
    Average voltage Vavg
    Phase currents
    Reactive power Q, Q1, Q2, Q3
    Power factor and displacement PF (signed, four quadrant)
    Unbalance voltage
    Calculated neutral current
    Voltage U21, U32, U13, V1, V2, V3
    Peak demand power PM, QM, SM
    Apparent power S, S1, S2, S3
    Demand power P, Q, S
    [Us] rated supply voltage
    40...300 V AC 45...65 Hz
    40...300 V DC
    network frequency
    60 Hz
    50 Hz
    [In] rated current
    5 A
    1 A
    type of network
    3P
    2P
    2P + N
    1P + N
    3P + N
    maximum power consumption in VA
    6 VA at 277 V between phase and neutral
    maximum power consumption in W
    2 W at 277 V
    display type
    7 segments LED
    display colour
    Red
    messages display capacity
    3 fields of 4 characters
    display digits
    12 digit(s) - 14.2 mm in height
    communication of data
    Net energy
    Energy metering
    Reading of time-stamped measurements and events
    Total energy
    tamperproof of settings
    Protected by access code
    sampling rate
    64 samples/cycle
    measurement current
    5…6000 mA
    Signal
    Current 0...12 A (impedance 0.3 MOhm)6 x
    Voltage (impedance 5 MOhm)4 x
    measurement voltage
    35…480 V AC 45...65 Hz between phases
    35…277 V AC 45...65 Hz between phase and neutral
    35…600 V AC 45...65 Hz between phases
    35…347 V AC 45...65 Hz between phase and neutral
    600…999000 V AC 45...65 Hz with external VT
    frequency measurement range
    45…65 Hz
    measurement accuracy
    Current +/- 0.5 %
    Voltage +/- 0.5 %
    Power +/- 0.5 %
    Frequency +/- 0.05 %
    Power factor +/- 0.01
    accuracy class
    Class 1 active energy conforming to IEC 62053-21
    Class 2 reactive energy conforming to IEC 62053-23
    Class 5P harmonic distorsion (I THD & U THD) conforming to IEC 61557-12
    Class 5P individual harmonics up to the 15th conforming to IEC 61557-12
    number of outputs
    0
    Demand intervals
    Configurable from 1 to 60 min
    information displayed
    Voltage (min/max)
    Current (min/max)
    Power factor (min/max)
    Frequency (min/max)
    Active power (min/max)
    Apparent power (min/max)
    Reactive power (min/max)
    Time (min/max)
    Demand current (past value)
    Demand current (present value)
    Demand power (past value)
    Demand power (present value)
    local signalling
    Green LED: activity
    Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
    Green LED: communication status
    communication port protocol
    Modbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
    communication port support
    RS485
    data recording
    Time stamping
    Energy consumption logs
    Min/max of instantaneous values
    material
    Polycarbonate
    flame retardance
    V-0 conforming to UL 94
    mounting mode
    Panel-mounted
    Flush-mounted
    mounting support
    Framework
    fixing mode
    By clamp
    installation category
    III
    type of installation
    Indoor installation
    measurement category
    Category III 480 V
    Category II 480…600 V
    electrical insulation class
    Class II
    connections - terminals
    Current circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s)
    Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
    Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
    Communication: screw clamp terminals 0.33…3.31 mm² cable(s)
    tightening torque
    Current circuit: 0.9…1 N.m Philips No 2 screwdriver
    Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver
    Control circuit: 0.9…1 N.m Philips No 2 screwdriver
    Communication: 0.9…1 N.m Philips No 2 screwdriver
    wire stripping length
    Current circuit: 3.68 mm
    Voltage circuit: 7 mm
    Control circuit: 7 mm
    Communication: 7 mm
    standards
    IEC 61010-1:ed. 3
    UL 61010-1:ed. 3
    product certifications
    CE conforming to IEC 61010-1
    CULus conforming to UL 61010-1
    CULus conforming to CSA C22.2 No 61010-1
    C-Tick
    width
    96 mm
    depth
    73 mm panel:
    13 mm outside:
    height
    96 mm
    net weight
    600 g
    Environment
    electromagnetic compatibility
    Electrostatic discharge conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
    Surge immunity test conforming to IEC 61000-4-5
    Conducted RF disturbances conforming to IEC 61000-4-6
    Magnetic field at power frequency conforming to IEC 61000-4-8
    Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
    Emission tests conforming to FCC part 15 class A
    overvoltage category
    III
    IP degree of protection
    IP51 front: conforming to IEC 60529
    IP30 body: conforming to IEC 60529
    relative humidity
    5…95 % at 50 °C
    pollution degree
    2
    ambient air temperature for operation
    -10…60 °C
    ambient air temperature for storage
    -20…70 °C
    operating altitude
    <= 2000 m
    service life
    7 year(s)
    Offer Sustainability
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Under investigation
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • Documents & Downloads

    Language
    • English
    • French
    User guide
    Date
    Size
    Add to My Documents
    Conzerv EM6400NG (Version 02)
    Date 13/2/19
    Size 11 MB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    ECDEM6400NG-V1a (Version 1.0)
    Date 6/5/16
    Size 648.1 KB
    End of Life Information
    Date
    Size
    Add to My Documents
    EOLI - EM6400NG Class 0.5 (Version 1.0)
    Date 20/6/18
    Size 411.7 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    PEP - EM6400NG Class 0.5 (Version 1.0)
    Date 20/6/18
    Size 440.2 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    RoHs China Declaration
    Date
    Size
    Add to My Documents
    Technical leaflet
    Date
    Size
    Add to My Documents
    EM6400NG Multi-function Meter Technical Datasheet (Version 1.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /