METSEEM6400NGRSCL5 Product picture Schneider Electric

Range: EM6400NG

Meters

METSEEM6400NGRSCL5

METSEEM6400NGRSCL5 Product picture Schneider Electric
Range: EM6400NG

Meters

METSEEM6400NGRSCL5

Conzerv Power and Energy meter - inst., pulse, RS485, THD, 15th Har, Class 0.5S

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range
    Conzerv
    product name
    EM6400NG RS-485
    device short name
    Conzerv EM6400NG
    product or component type
    Energy meter
    Complementary
    power quality analysis
    Up to the 15th harmonic
    device application
    Power monitoring
    type of measurement
    Active and reactive power
    Active and reactive energy
    Apparent energy
    Voltage
    Current
    Frequency
    Apparent power
    metering type
    Active power P, P1, P2, P3
    Apparent power S, S1, S2, S3
    Demand current I1, I2, I3
    Peak demand currents
    Phase currents
    Reactive power Q, Q1, Q2, Q3
    Voltage U21, U32, U13, V1, V2, V3
    Average voltage Vavg
    Average current Iavg
    Unbalance current
    Unbalance voltage
    Power factor and displacement PF (signed, four quadrant)
    Active, reactive, apparent energy (signed, four quadrant)
    Calculated neutral current
    Demand power P, Q, S
    Peak demand power PM, QM, SM
    [Us] rated supply voltage
    40...300 V AC 45...65 Hz
    40...300 V DC
    network frequency
    50 Hz
    60 Hz
    [In] rated current
    1 A
    5 A
    type of network
    1P + N
    2P
    2P + N
    3P
    3P + N
    power consumption in VA
    < 6 VA at 277 V AC between phase and neutral
    power consumption in W
    < 2 W at 277 V DC
    display type
    7 segments LED
    display colour
    Red
    messages display capacity
    3 fields of 4 characters
    display digits
    12 digit(s) - 14.2 mm in height
    communication of data
    Energy metering
    Reading of time-stamped measurements and events
    Net energy
    Total energy
    tamperproof of settings
    Protected by access code
    sampling rate
    64 samples/cycle
    measurement current
    5...6000 mA
    Signal
    Current 0...12 A (impedance 0.3 MOhm) 6 terminal(s)
    Voltage (impedance 5 MOhm) 4 terminal(s)
    measurement voltage
    35...480 V AC 45...65 Hz between phases
    35...277 V AC 45...65 Hz between phase and neutral
    35...600 V AC 45...65 Hz between phases
    35...347 V AC 45...65 Hz between phase and neutral
    600...999000 V AC 45...65 Hz with external VT
    frequency measurement range
    45...65 Hz
    measurement accuracy
    +/- 0.05 % frequency
    +/- 0.5 % current
    +/- 0.5 % voltage
    +/- 0.5 % power
    +/- 0.01 power factor
    accuracy class
    Class 2 (reactive energy according to IEC 62053-23)
    Class 1 (active energy according to IEC 62053-21)
    Class 5P (harmonic distorsion (I THD & U THD) according to IEC 61557-12)
    Class 5P (individual harmonics up to the 15th according to IEC 61557-12)
    number of outputs
    0
    Demand intervals
    Configurable from 1 to 60 min
    information displayed
    Voltage min/max
    Current min/max
    Power factor min/max
    Frequency min/max
    Active power min/max
    Apparent power min/max
    Reactive power min/max
    Time min/max
    Demand current past value
    Demand current present value
    Demand power past value
    Demand power present value
    local signalling
    Green LED : activity
    Green LED : communication status
    Red LED : output signal
    communication port protocol
    Modbus 2 wires, : 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps, even/odd or none, insulation: 2500 V
    communication port support
    RS485
    data recording
    Min/max of instantaneous values
    Time stamping
    Energy consumption logs
    material
    Polycarbonate
    flame retardance
    V-0 UL 94 conforming to UL 94 V-0
    mounting mode
    Flush-mounted
    Panel-mounted
    mounting support
    Framework
    fixing mode
    By clamp
    installation category
    III
    type of installation
    Indoor installation
    measurement category
    Category III up to <= 480 V
    Category II up to > 480...600 V
    electrical insulation class
    Class II
    connections - terminals
    Current circuit : bottom screw clamp terminals 2.08...3.31 mm²
    Voltage circuit : top screw clamp terminals 0.82...3.31 mm²
    Control circuit : top screw clamp terminals 0.82...3.31 mm²
    Communication : screw clamp terminals 0.33...3.31 mm²
    tightening torque
    Current circuit : 0.9...1 N.m with Philips No 2
    Voltage circuit : 0.9...1 N.m with Philips No 2
    Control circuit : 0.9...1 N.m with Philips No 2
    Communication : 0.9...1 N.m with Philips No 2
    wire stripping length
    Communication : 7 mm
    Current circuit : 3.68 mm
    Voltage circuit : 7 mm
    Control circuit : 7 mm
    standards
    IEC 61010-1 ed. 3
    UL 61010-1 ed. 3
    product certifications
    CE conforming to IEC 61010-1
    CULus conforming to UL 61010-1
    CULus conforming to CSA C22.2 No 61010-1
    C-Tick
    width
    96 mm
    depth
    73 mm panel
    13 mm outside
    height
    96 mm
    product weight
    600 g
    Environment
    electromagnetic compatibility
    ● electrical fast transient/burst immunity test, conforming to IEC 61000-4-4
    ● conducted RF disturbances, conforming to IEC 61000-4-6
    ● radiated radio-frequency electromagnetic field immunity test, conforming to IEC 61000-4-3
    ● voltage dips and interruptions immunity test, conforming to IEC 61000-4-11
    ● electrostatic discharge, conforming to IEC 61000-4-2
    ● surge immunity test, conforming to IEC 61000-4-5
    ● magnetic field at power frequency, conforming to IEC 61000-4-8
    ● emission tests, conforming to FCC part 15 class A
    overvoltage category
    III
    IP degree of protection
    IP30 (body) conforming to IEC 60529
    IP51 (front) conforming to IEC 60529
    relative humidity
    5...95 % 50 °C
    pollution degree
    2
    ambient air temperature for operation
    -10...60 °C
    ambient air temperature for storage
    -20...70 °C
    operating altitude
    <= 2000 m
    service life
    > 7 yr
    Offer Sustainability
    RoHS (date code: YYWW)
    Product environmental profile
    Product end of life instructions
  • Documents & Downloads

    Language
    • English
    Catalogue Page
    Date
    Size
    Add to My Documents
    EM6400NG Multi-function Meter Catalogue Pages
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Date 10/5/16
    Size 648.1 KB
    End of life manual
    Date
    Size
    Add to My Documents
    Date 14/7/18
    Size 411.7 KB
    Product environmental
    Date
    Size
    Add to My Documents
    Date 14/7/18
    Size 440.2 KB
    Technical leaflet
    Date
    Size
    Add to My Documents
    EM6400NG Multi-function Meter Technical Datasheet
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.