View all EasyLogic PM2000 series
METSEPM2130D Product picture Schneider Electric

METSEPM2130D

METSEPM2130D Product picture Schneider Electric
METSEPM2130D

EasyLogic PM2130, Power & Energy meter, up to 31stH, LED, RS485, class 0.5S

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    EasyLogic
    product name
    EasyLogic PM2100
    device short name
    PM2130
    product or component type
    Power meter
    Complementary
    device application
    Sub billing
    Power monitoring
    power quality analysis
    total harmonic distortion
    up to the 31st harmonic
    type of measurement
    Apparent power min/max, total
    Active and reactive power min/max, total
    Current min/max, avg
    Voltage min/max, avg
    Frequency min/max, avg
    Total current harmonic distortion THD (I) per phase
    Total voltage harmonic distortion THD (U) per phase
    Power factor min/max, avg
    Apparent energy total
    Active and reactive energy total
    metering type
    Peak demand power PM, QM, SM
    Peak demand currents
    Calculated neutral current
    Reactive power Q, Q1, Q2, Q3
    Current I, I1, I2, I3
    Voltage U, U21, U32, U13, V, V1, V2, V3
    Apparent power S, S1, S2, S3
    Active, reactive, apparent energy (signed, four quadrant)
    Active power P, P1, P2, P3
    Demand power P, Q, S
    Unbalance current
    accuracy class
    Class 1 reactive energy conforming to IEC 62053-24
    Class 0.5S active energy conforming to IEC 62053-22
    Class 5 harmonic distorsion (I THD & U THD)
    measurement accuracy
    Apparent power +/- 0.5 %
    Active energy +/- 0.5 %
    Reactive energy +/- 1 %
    Active power +/- 0.5 %
    Voltage +/- 0.5 %
    Power factor +/- 0.01
    Current +/- 0.5 %
    Frequency +/- 0.05 %
    measurement current
    5…6000 mA
    measurement voltage
    35…480 V AC 50/60 Hz between phases
    20…277 V AC 50/60 Hz between phase and neutral
    480…999000 V AC 50/60 Hz with external VT
    frequency measurement range
    45…65 Hz
    [Us] rated supply voltage
    80...277 V AC 45...65 Hz +/- 10 %
    100...277 V DC +/- 10 %
    network frequency
    60 Hz
    50 Hz
    ride-through time
    50 ms 120 V AC typical
    50 ms 230 V AC typical
    50 ms 125 V DC typical
    [In] rated current
    1 A
    5 A
    maximum power consumption in VA
    8 VA at 277 V AC
    maximum power consumption in W
    3.3 W (power lines (AC))
    3.3 W at 277 V (power lines (DC))
    input impedance
    Current (impedance <= 0.3 mOhm)
    Voltage (impedance > 5 MOhm)
    tamperproof of settings
    Protected by access code
    display type
    7 segments LED
    display colour
    Red
    messages display capacity
    3 fields of 4 characters
    display digits
    12 digit(s) - 14.2 mm in height
    Demand intervals
    Configurable from 1 to 60 min
    information displayed
    Demand current (past value)
    Demand current (present value)
    Demand power (past value)
    Demand power (present value)
    Voltage
    Current
    Frequency
    Energy consumption
    Harmonic distortion
    Power factor
    Active power
    Apparent power
    Reactive power
    Unbalanced in %
    control type
    3 x button
    local signalling
    Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
    Green LED: module operation and integrated communication
    number of inputs
    0
    number of outputs
    0
    communication port protocol
    Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
    communication port support
    Screw terminal block: RS485
    data recording
    Min/max for 8 parameters
    Energy consumption logs
    Time stamping
    Power logs
    function available
    Real time clock
    sampling rate
    64 samples/cycle
    cybersecurity
    Enable/disable communication ports
    communication service
    Remote monitoring
    product certifications
    CE conforming to IEC 61010-1
    CULus conforming to UL 61010-1
    CULus conforming to CSA C22.2 No 61010-1
    RCM
    EAC
    C-Tick
    mounting mode
    Clip-on
    mounting position
    Vertical
    mounting support
    Framework
    provided equipment
    1 x installation guide
    measurement category
    Category III 480 V
    Category II 480…600 V
    electrical insulation class
    Double insulation
    Class II
    flame retardance
    V-0 conforming to UL 94
    connections - terminals
    Current transformer: screw connection (bottom) 6
    Voltage inputs: screw connection (top) 4
    material
    Polycarbonate
    width
    96 mm
    depth
    76.09 mm total:
    61.64 mm embedded:
    height
    96 mm
    net weight
    300 g
    targeted country
    India
    Environment
    service life
    7 year(s)
    IP degree of protection
    IP54 front: conforming to IEC 60529
    IP30 body: conforming to IEC 60529
    relative humidity
    5…95 % at 50 °C
    pollution degree
    2
    ambient air temperature for operation
    -10…60 °C
    ambient air temperature for storage
    -25…70 °C
    operating altitude
    <= 2000 m
    electromagnetic compatibility
    Electrostatic discharge conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
    Surge immunity test conforming to IEC 61000-4-5
    Conducted RF disturbances conforming to IEC 61000-4-6
    Magnetic field at power frequency conforming to IEC 61000-4-8
    Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
    Emission tests conforming to FCC part 15 class A
    overvoltage category
    III
    Offer Sustainability
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Under investigation
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • Documents & Downloads

    Language
    • English
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    PM2100 Environmental Profile (Version 1.0)
    Date 8/12/15
    Size 368.4 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    RoHs China Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /