    range of product
    Modicon TM3
    product or component type
    Discrete I/O module
    range compatibility
    Modicon M221
    Modicon M241
    Modicon M251
    discrete input number
    16 input conforming to IEC 61131-2 Type 1
    discrete input logic
    Sink or source (positive/negative)
    discrete input voltage
    24 V
    discrete input current
    7 mA for input
    discrete output type
    Relay normally open
    discrete output number
    8
    discrete output logic
    Positive or negative
    discrete output voltage
    24 V DC for relay output
    240 V AC for relay output
    discrete output current
    2000 mA for relay output
    Complementary
    discrete I/O number
    24
    current consumption
    5 mA at 5 V DC via bus connector at state off
    0 mA at 24 V DC via bus connector at state on
    0 mA at 24 V DC via bus connector at state off
    65 mA at 5 V DC via bus connector at state on
    discrete input voltage type
    DC
    voltage state 1 guaranteed
    15...28.8 V for input
    current state 1 guaranteed
    >= 2.5 mA for input
    voltage state 0 guaranteed
    0...5 V for input
    current state 0 guaranteed
    <= 1 mA for input
    input impedance
    3.4 kOhm
    response time
    4 ms for turn-on
    4 ms for turn-off
    current per output common
    7 A
    mechanical durability
    20000000 cycles
    minimum load
    10 mA at 5 V DC for relay output
    local signalling
    1 LED per channel green for I/O state
    electrical connection
    Removable spring terminal block pitch 3.81 mm with 17 terminal(s) of 1.5 mm² connection capacity for inputs
    Removable spring terminal block pitch 3.81 mm with 11 terminal(s) of 1.5 mm² connection capacity for outputs
    cable distance between devices
    Unshielded cable: 30 m for regular input
    insulation
    Non-insulated between inputs
    500 V AC between output and internal logic
    Non-insulated between outputs
    500 V AC between input and internal logic
    1500 V AC between input groups and output groups
    750 V AC between open contact
    marking
    CE
    mounting support
    Top hat type TH35-15 rail conforming to IEC 60715
    Top hat type TH35-7.5 rail conforming to IEC 60715
    Plate or panel with fixing kit
    height
    90 mm
    depth
    84.6 mm
    width
    42.9 mm
    Environment
    standards
    EN/IEC 61131-2
    EN/IEC 61010-2-201
    product certifications
    C-Tick
    cULus
    resistance to electrostatic discharge
    4 kV (on contact) conforming to EN/IEC 61000-4-2
    8 kV (in air) conforming to EN/IEC 61000-4-2
    resistance to electromagnetic fields
    10 V/m at 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
    3 V/m at 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
    1 V/m at 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
    resistance to magnetic fields
    30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
    resistance to fast transients
    2 kV for relay output conforming to EN/IEC 61000-4-4
    1 kV for I/O conforming to EN/IEC 61000-4-4
    surge withstand
    1 kV for input in common mode conforming to EN/IEC 61000-4-5
    2 kV for output in common mode conforming to EN/IEC 61000-4-5
    resistance to conducted disturbances
    10 Vrms at 0.15...80 MHz conforming to EN/IEC 61000-4-6
    3 Vrms at spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
    electromagnetic emission
    Radiated emissions, test level: 40 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 30...230 MHz) conforming to EN/IEC 55011
    Radiated emissions, test level: 47 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011
    ambient air temperature for operation
    -10...55 °C for horizontal installation
    -10...35 °C for vertical installation
    ambient air temperature for storage
    -25...70 °C
    relative humidity
    10...95 % without condensation in operation
    10...95 % without condensation in storage
    IP degree of protection
    IP20 with protective cover in place
    pollution degree
    2
    operating altitude
    0...2000 m
    storage altitude
    0...3000 m
    vibration resistance
    3.5 mm (vibration frequency: 5...8.4 Hz) on DIN rail
    3 gn (vibration frequency: 8.4...150 Hz) on DIN rail
    3.5 mm (vibration frequency: 5...8.4 Hz) on panel
    3 gn (vibration frequency: 8.4...150 Hz) on panel
    shock resistance
    15 gn (test wave duration:11 ms)
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
  • Documents & Downloads

    Language
    • English
    Catalogue
    Date
    Size
    Add to My Documents
    Date 2/5/18
    Size 3.8 MB
    User guide
    Date
    Size
    Add to My Documents
    Date 20/8/18
    Size 9.1 MB
    Date 23/5/18
    Size 8.2 MB
    Date 23/5/18
    Size 7.7 MB
    Date 23/5/18
    Size 7.9 MB
    Date 23/5/18
    Size 2.7 MB
    Date 1/3/18
    Size 3.2 MB
    Date 1/3/18
    Size 6.9 MB
    CAD
    Date
    Size
    Add to My Documents
    Date 19/10/15
    Size 14 MB
    Date 21/7/16
    Size 15.2 MB
    Date 25/12/15
    Size 17.6 MB
    Date 25/12/15
    Size 16.3 MB
    Certificate
    Date
    Size
    Add to My Documents
    Date 12/9/17
    Size 213.5 KB
    Instruction sheet
    Date
    Size
    Add to My Documents
    Date 12/9/17
    Size 3.9 MB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Date 21/7/17
    Size 285.5 KB
    Date 24/9/17
    Size 565.5 KB
    End of life manual
    Date
    Size
    Add to My Documents
    Marine certificate
    Date
    Size
    Add to My Documents
    Date 24/9/17
    Size 171.3 KB
    Date 18/10/16
    Size 1.5 MB
    Date 12/7/17
    Size 218.1 KB
    Product environmental
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    (*)
    8.5 mm/0.33 in. when the clamp is pulled out.


  • Mounting and Clearance

    Spacing Requirements



    Mounting on a Rail


    Incorrect Mounting



    Mounting on a Panel Surface


    (1)
    Install a mounting strip

    Mounting Hole Layout



  • Connections and Schema

    Digital Mixed I/O Module (24-channel)
    Wiring Diagram (Source)


    (*)
    Type T fuse
    (1)
    The COM0, COM1 and COM2 terminals are not connected internally.
    (2)
    To improve the life time of the contacts, and to protect from potential inductive load damage, it is recommended to connect a free wheeling diode in parallel to each inductive DC load or an RC snubber in parallel of each inductive AC load.
    (A)
    Sink wiring (positive logic)
    (C)
    Source wiring (positive logic)

    Wiring Diagram (Sink)


    (*)
    Type T fuse
    (1)
    The COM0, COM1 and COM2 terminals are not connected internally.
    (2)
    To improve the life time of the contacts, and to protect from potential inductive load damage, it is recommended to connect a free wheeling diode in parallel to each inductive DC load or an RC snubber in parallel of each inductive AC load.
    (B)
    Source wiring (negative logic)
    (D)
    Sink wiring (negative logic)