  • Main
    range of product
    OsiSense XM
    product or component type
    Electronic pressure sensors
    device short name
    ZMLP
    Complementary
    display range
    -14.5...6000
    [Us] rated supply voltage
    24 V DC SELV, voltage limit: 17...33 V
    current consumption
    <= 50 mA
    electrical connection
    M12 female connector with 2 pins
    M12 male connector with 4 pins
    type of output signal
    Discrete
    discrete output type
    NPN solid state - 2 NO/NC programmable
    switching function
    Hysteresis
    maximum switching current
    200 mA
    voltage drop
    <= 2 V
    adjustable range of switching point on rising pressure
    5...98 % of selected display range
    minimum differential travel
    10 % of selected display range
    marking
    CE
    front material
    Polyester
    housing material
    PBT Valox
    operating position
    Any position
    protection type
    Overload protection
    Overvoltage protection
    Reverse polarity
    Short-circuit protection
    response time on output
    <= 3 ms for discrete output
    display type
    4 digits 7 segments
    local signalling
    2 LEDs yellow for light ON when switch is actuated
    response time
    300 ms
    delay first up
    <= 100 ms
    accuracy
    <= - 0.1 % of the measuring range
    measurement accuracy
    <= 1 % of the measuring range
    display accuracy
    <= 1 % of the measuring range
    mechanical durability
    >= 10000000 cycles
    depth
    42 mm
    height
    77 mm
    width
    41 mm
    product weight
    0.103 kg
    [Uimp] rated impulse withstand voltage
    0.5 kV DC
    Environment
    product certifications
    cULus
    EAC
    standards
    EN/IEC 61000-6-2
    EN/IEC 61000-6-4
    UL 508
    ambient air temperature for operation
    -25...70 °C
    ambient air temperature for storage
    -30...80 °C
    IP degree of protection
    IP65 conforming to EN/IEC 60529
    IP67 conforming to EN/IEC 60529
    IP69K conforming to DIN 40050
    vibration resistance
    5 gn at 10...2000 Hz conforming to EN/IEC 60068-2-6
    shock resistance
    25 gn conforming to EN/IEC 60068-2-27
    electromagnetic compatibility
    Immunity to conducted RF disturbances at 10 V, 0.15...80 MHz conforming to EN/IEC 61000-4-6
    Surge immunity test at 1 kV conforming to EN/IEC 61000-4-5
    Electrical fast transient/burst immunity test at 2 kV conforming to EN/IEC 61000-4-4
    Susceptibility to electromagnetic fields at 10 V/m, 80...2000 MHz conforming to EN/IEC 61000-4-3
    Electrostatic discharge immunity test at 8 kV air, 4 kV contact conforming to EN/IEC 61000-4-2
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
  • Documents & Downloads

    Language
    • English
    • French
    Catalogue
    Date
    Size
    Add to My Documents
    Electronic sensors for pressure control OsiSense XM (Version 5.0)
    CAD
    Date
    Size
    Add to My Documents
    CAD files for ZMLPA2N0SH: 2 discrete outputs, Hysteresis mode, connector M12 (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    ZMLP... switches with 4 digits display - UL certification record (Version 1.0)
    ZMLP... switches with 4 digits display - cUL certification record (for Canada) (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    ZMLP... Pressure display and switch device, Instruction Sheet (Version 03)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    ZMLP... switches with 4 digits display - Supplier's declaration of conformity to Australian regulations (Version 1.0)
    ZMLP... switches with 4 digits display - EU declaration of conformity (Version 1.0)
    End of Life Information
    Date
    Size
    Add to My Documents
    ZMLPA2P0SH switch & display device for pressure transmitter, Product End-of-Life Instructions (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 6/3/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    ZMLPA2P0SH switch & display device for pressure transmitter, Product Environmental Profile (Version 2.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 6/3/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



    Dimensions
    Switch with Metal Bracket for Fixing Horizontally



    Dimensions
    Switch with Metal Bracket for Fixing Vertically or on an Inlet Pipe



  • Connections and Schema

    Connections and Schema
    Output M12 Male Connector Wiring


    (1)
    Out 1
    (2)
    Out 2


    Connections and Schema
    Input M12 Female Connector Wiring


    (1)
    l in = 4-20 mA


  • Performance Curves

    Two Switching Outputs Description. Hysteresis Mode

    The hysteresis switching mode is typically used for the pumping applications


    X :
    Time
    Y :
    Pressure
    (1)
    Output
    (2)
    Fixed hysteresis = 10% of the selected display range
    SP1/SP2 :
    Set points (adjustable from 11% to 98% nominal pressure)